Case Study:

BBU w blower conv.jpg
Problem:

EPA standards required this company to feed Enviroblend® into their dust collection system at a precisely controlled rate of 13.6 kg per hour, so the emissions would be at an acceptable level. They also required a digital verification that the material was accurately discharging.

Solution:

Hapman used a Bulk Bag Unloader with bag agitation to discharge the material into a Feeder. The Feeder meter-fed the Enviroblend into a Eductor. A 4 HP Roton Blower then conveyed the material into the bag house. The use of load cells and an IQ Plus® 510 Batch Indicator verified that the feeder was constantly discharging the material. The digital readout provided up to the second information and a low level sensor in the Feeder would alarm them when the bag was empty.

Result:

This system provided the customer with a very accurate automated system. The only manpower required was the replacement of the Bulk Bag every 2½ days.